JK-SLF-210 sterile laminar flow isolation device
JK-SLF-210 sterile laminar flow isolation device
Introduction
The device is also known as Horizontal laminar flow clean beds. It effectively achieve the effects of physical isolation in the form of vertical laminar flow clean air. Especially for the blood of patients, burn patients, respiratory diseases and Chemoradiotherapy such as low immunity patients. General wards with placing beds are equipped with the isolation unit, which will be composed of sterile environment and reduce the risk of infection of patients.
Features
Clean and sterile isolation room
1 Use thin VAV air supply system clean screen of Janpanese AIR TECH technology.
2 Large size and high-efficiency air filters last longer
3 Filtration efficiency of ≥ 0.3 micron on the dust and bacteria is ≥ 99.99%
4 Ensure isolation room clean and sterile
Ultra-low noise design combination of human
1 Flexible level of air make People feel comfortable
2 Routine operation less than 38DB,ultra-low mute
3 Sufficient net height and curtain of high-transparent and health make patients feel cheerful without depression
4 Vertical slice soft curtain not only facilitate the treatment,but also facilitate disinfection
Safe and reliable facilities
1 Strictly accordance with international advanced design of electrical safety standards
2 Multiple safety protection measures
3 Lighting and UV light interlocking control
Cost-effective
1 Standard components, factory-scale manufacturing, scene quickly assembly
2 compared to the traditional construction of clean wards,it is more cost- effective
JK-SLF-210 Medical air isolation unit | ||
Cleanliness | ISOS(100 level) | |
wind speed | 0.17m/s | 0.24m/s |
Noise | 46dB(A) | 62dB(A) |
Power | AC220V. Single-phase.51Hz | |
Maximum Power | 180W | |
Bacterial colonies | ≤1/(Φ90mm·0.5h) | |
Dimensions of accessory | 2100(L)×1000(W)×2300(H)mm | |
Internal net Size of accessory | 2000(L)×1000(W)×1800(H)mm | |
Fluorescent / UV light | 30W×1/18W×1 |
JK-SLF-210 sterile laminar flow isolation device